Setting the record straight

Numerous stories have cycled through the channels regarding the experiments accomplished at Texas A&M during 1992. To assist in setting the record straight, I am posting the facts without editing from the signed laboratory notes recorded by Dr. Guang Lin and Dr. R. Bhradwaj (researchers in Dr. John Bockris Department). No other explanation is required.

Experiments Main Results Comments  
Thermal 0
April 21, 1992
Beta decay shows 18.5 hour half life This formula had no silver. Joe indicated that this is not the correct recipe.  
Thermal I
April 30, 1992
Two times increase in Pt was observed. The sample was cuppeled 6 times and one of the six showed Au and Pt 148 ppm and 167 ppm. Bonder Clag result showed concentration effect. One out of six done a TAMU showed increase in Au and Pt.  
Thermal II
May 22, 1992
250 => 450 ppm of gold present in the (final) product. An increase in Pd was observed too. Experiment done in the present of Joe (Joe Champion) and Monti (Roberto Monti) Analysis done by South Africa, Chemax Laboratories and TAMU.  
Thermal III
May 27, 1992
The weight of the bead from chemical mixture with Hg was 3 - 4 times bigger than without Hg. No further analysis was done because the (before sample) mineral contained no gold or silver.  
Thermal IV
May 30, 1992
A large amount of gold about 1,700 ppm (of mineral sand) was found. Ore contained 4.34 ppm of Ag and 1,46 ppm of Au as analysis sent by Action Mining. This is calculated with respect to (the weight of) ore not the total mixture. It is five times less in relation to total mixture. Experiment with Joe and Monti present.  
Thermal V
June 7, 1992
The gold concentration found in the product was about 178 ppm (corresponding to raw material). This was a repeat of Thermal II and Joe and Monti present.  
Thermal VI
June 8, 1992
No gold was found in both experiments (with and without Hg in the raw material). The Au and Ag distribution in the mineral may not of be uniform. Done by Lin.  
Thermal VII
June 10, 1992
Same recipe as in Thermal II and V. The mixture became half after firing. No formation of extra gold. Experiment done by Lin, Bhardwaj and Minevski. Only concentration effect. Samples analyzed by Chemax Laboratory. Joe and Monti not present.  
Thermal VIII
June 23, 1992
Same recipe as in Thermal II and V. Doubling of Au. No formation of extra gold. Experiment done by Lin, Bhardwaj and Minevski. Only concentration effect. Samples analyzed by Chemax Laboratory. Joe and Monti not present  
Thermal IX
June 24, 1992
Same recipe as in Thermal II and V. Doubling of Au. Experiment done by Lin, Bhardwaj and Minevski. Only concentration effect. Samples analyzed by Chemax Laboratory. Joe and Monti not present  
Thermal X
July 12, 1992
Same recipe of as Thermal II and V. The gold was 0.6 ppm in solution of 50ml which is equivalent of 0.3 ppm in total mixture of 1615 g. Experiment done by Bhardwaj and Monti. Analysis done by ICP in soil science department after cuppeling.  
Thermal XI
August 21, 1992
Same recipe as Thermal; II and IV. Sample given for gamma radiation to cyclotron laboratory. Done by Dr. Lin. Small gamma radiation was detected using giga detector. Increase from 30 cpm to 60-70 cpm. Gamma showed no signal.  
Thermal XIB
October 27, 1992
Same recipe as Thermal II. Gamma records showed no gamma detected. Done by Lin with person from Savannah River .
Thermal XII
(No date)
Same recipe as Thermal II. This was for beta detection. The beta was 1.56/sec before ignition and 1.78/sec after ignition. Beta was detected by Dr. Lin and Bhardwaj. No significant increase in beta. Sample analyzed by Chemax Laboratory. Result less than 1 ppm  
Thermal XIII
November 3, 1992
Sample recipe of Thermal II. The product after ignition is 841 grams The analysis done by dissolving the powder directly in aqua regia shows 0 ppm of gold. Beta counting was recorded by Bhardwaj and Lin for 3 days with half life time about 20-23 hours. Chemax Laboratory analysis before ignition 0.031 ppm and after 0,095 ppm. Analysis done at TAMU shows 0.085 ppm after ignition.  
Thermal XIV
December 6, 1992
Same recipe as Thermal II and V. Direct analysis of powder before and after in aqua regia shows zero gold. Done by Bhardwaj and Lin. Chemax Laboratory analysis shows no gold. Cuppeling by Bhardwaj shows 0.09 ppm gold  
THERMAL XV
December 16, 1992
Same as Thermal IV. Chemax analysis shows doubling of Au and Pt. No extra gold or Pt formed.  
Thermal XVI
January 6, 1993
Patel Formula Total 5.16 grams of silver bead was recovered after cuppeling. Dissolved in nitric acid. 0.45 milligram of gold was found. The before sample is given for nuclear activation analysis.  

Send mail to jchampion@citlink.net with questions or comments about this web page.